Rangsons Aerospace
Products · Division 01 · Aerospace Cooling Systems & Pod Thermal Control

Aerospace Cooling Systems & Heat Exchangers in Bangalore, India

Custom thermal management products and aircraft cooling solutions manufactured in Bangalore and Mysore, Karnataka: NADCAP vacuum-brazed compact plate-fin heat exchangers, Fuel-Cooled Oil Coolers (FCOC), CEMILAC AESA radar cold plates, and MIL-STD-810 qualified EW Pod Cooling Systems.

CEMILAC & DGAQA Approved
NADCAP Vacuum Brazing & AS9100D
ISRO Gaganyaan Space Heritage
MIL-STD-810H & DO-160G Qualified
Mysuru NADCAP Manufacturing & Bengaluru CFD/FEA R&D

11 Aerospace Cooling Systems & Custom Thermal Management Products

Request Thermal CAD & CFD Review
Up to 25 kW
Multi-Core Heat Rejection

Air-to-Air, Air-to-Liquid, LTL & Three-Core HX

0.006 °C/W
Minimum Thermal Impedance

0.1 mm Micro-Fin AESA & 8-Slot ATR Cold Plates

< 5×10⁻⁸ sccs
Helium Mass-Spec Leak Rate

100% NADCAP Vacuum-Brazed Core Verification

3.5 kW @ Mach 0.95
Self-Contained EW Pod Cooling

Monoblock, LCM, Pump & Accumulator up to 45,000 ft

Category 01 · Plate-Fin & Multi-Stream Cores

Compact Heat Exchangers & Aircraft Cooling Systems

Engineered in Aluminum 3003 and 6061-T6 using NADCAP vacuum brazing, our aerospace cooling solutions and custom thermal management products maximize heat rejection across cockpit Environmental Control Systems (ECS), aircraft cooling loops, and radar payloads.

Compact Heat Exchanger · ECSModel / Code: RAPL-HX-ATA

Air-to-Air Compact Plate-Fin Heat Exchanger

Cross-flow plate-fin air-to-air compact heat exchanger engineered for aircraft Environmental Control Systems (ECS) and military cockpit air conditioning loops.

Key Engineering Features

  • High heat-transfer surface area-to-volume ratio for cramped dorsal and fuselage bays
  • Corrugated fin geometry optimized for low aerodynamic pressure drop and high effectiveness
  • Flight-qualified for fighter aircraft and military transport cockpit ECS cooling loops
Target Platforms:Fighter & Trainer Cockpit ECSMilitary Transport Bleed-Air Pre-CoolingUAV Environmental Conditioning
Rangsons Aerospace Air-to-Air Compact Plate-Fin Heat Exchanger (RAPL-HX-ATA)

Technical Specifications

Up to 5 kW Heat Rejection
Heat Transfer Rate
Up to 5 kW
Fin Density
22 FPI (Fins Per Inch)
Operating Temperature
-55°C to +250°C
Max Pressure Drop
< 1.5 kPa at nominal flow
Material
Brazed Aluminum Alloy 3003
Configuration
Cross-Flow Plate-Fin
Weight
1.8 Kg
Dimensions
20.0 × 20.0 × 12.0 cm
Liquid-to-Air Radiator · EGW / PAOModel / Code: RAPL-HX-ATL

Air-to-Liquid Compact Heat Exchanger

High-efficiency vacuum-brazed liquid-to-air radiator designed to reject heat from secondary avionics and radar liquid cooling loops (EGW, PAO, PGW) into ram air or forced axial-fan airflow.

Key Engineering Features

  • Vacuum-brazed flat-tube core architecture providing 450 PSI burst containment
  • High-density 24 FPI louvered fin array maximizing heat rejection in shallow envelopes
  • Integrates directly with 400Hz high-volume axial fans for ground-standby or low-speed flight
Target Platforms:Airborne Radar Liquid LoopsPodded Sensor RadiatorsGround Mobile Defence Electronics
Rangsons Aerospace Air-to-Liquid Compact Heat Exchanger (RAPL-HX-ATL)

Technical Specifications

Up to 8 kW · 450 PSI Burst
Heat Transfer Rate
Up to 8 kW
Fin Density
24 FPI (Louvered Fins)
Operating Temperature
-40°C to +125°C
Coolant Medium
EGW / PAO / PGW
Burst Pressure
450 PSI
Material
Vacuum-Brazed Aluminum
Weight
2.4 Kg
Dimensions
28.0 × 22.0 × 8.5 cm
Dual-Loop Isolation · >85% EffectivenessModel / Code: RAPL-HX-LTL

Liquid-to-Liquid Plate-Fin Heat Exchanger

Ultra-compact vacuum-brazed plate-fin liquid-to-liquid heat exchanger providing complete hydraulic isolation and high-flux thermal transfer between primary dielectric and secondary coolant loops.

Key Engineering Features

  • Ultra-compact 1.5 kg envelope engineered for dense avionics and naval radar cabinets
  • Complete hydraulic isolation between incompatible primary PAO and secondary glycol circuits
  • 100% Helium mass-spectrometry leak tested for cyclic pressure endurance
Target Platforms:AESA Radar Primary-to-Secondary Loop CouplingShipborne Phased-Array CoolingSpacecraft & Submersible Fluid Conditioning
Rangsons Aerospace Liquid-to-Liquid Plate-Fin Heat Exchanger (RAPL-HX-LTL)

Technical Specifications

Up to 12 kW · > 85% Effectiveness
Heat Transfer Rate
Up to 12 kW
Operating Pressure
Up to 150 PSI (both loops)
Fluid Mediums
PAO, EGW, Deionized Water, PGW
Thermal Effectiveness
> 85%
Helium Leak Rate
< 1 × 10⁻⁶ sccs Helium
Material
Brazed Aluminum Alloy 6061 / 3003
Weight
1.5 Kg
Dimensions
18.0 × 10.0 × 8.0 cm
3 Independent Circuits · Up to 25 kWModel / Code: RAPL-HX-3C

Three-Core Multi-Stream Heat Exchanger

Integrated multi-fluid compact heat exchanger consolidating three distinct flow circuits—such as engine lubrication oil, ECS air, and EGW electronics coolant—inside a single vacuum-brazed assembly.

Key Engineering Features

  • Consolidates three discrete heat exchangers into one monolithic LRU to cut airframe weight
  • Eliminates redundant interconnect plumbing, mounting brackets, and potential leak joints
  • Internal manifold geometry engineered via FEA to prevent thermal-gradient stress cracking
Target Platforms:Integrated Aircraft Power & Thermal ManagementRotary-Wing Multi-Fluid Cooling BaysArmored Combat Vehicle Powerpacks
Rangsons Aerospace Three-Core Multi-Stream Heat Exchanger (RAPL-HX-3C)

Technical Specifications

Combined up to 25 kW (3 Loops)
Heat Transfer Rate
Combined up to 25 kW
Flow Circuits
3 independent isolated loops
Operating Pressure
Up to 400 PSI (fluid circuits)
Fin Geometry
Mixed Offset Strip & Louvered
Material
Brazed Aluminum Alloy
Qualification
Airborne military environmental qualification
Weight
4.8 Kg
Dimensions
38.0 × 26.0 × 18.0 cm
Category 02 · Propulsion, Gearbox & APU Lubrication Cooling

Fuel-Cooled Oil Coolers (FCOC) & Air-Cooled Oil Coolers

High-pressure propulsion and transmission heat exchangers built to manage Jet A-1 aviation turbine fuel, MIL-PRF-23699 synthetic turbine oil, and MIL-PRF-5606/83282 hydraulic fluids under severe engine vibration and pressure-impulse cycles.

Jet A-1 / MIL-PRF-23699 · Dual-BarrierModel / Code: RAPL-HX-FCOC

Fuel-Cooled Oil Cooler (FCOC)

High-reliability shell-and-tube and plate-fin Fuel-Cooled Oil Cooler (FCOC) engineered for aero-engine, turbofan, and accessory gearbox lubrication cooling using aviation turbine fuel as the heat sink.

Key Engineering Features

  • Regenerative cycle preheats Jet A-1 fuel against icing while stabilizing turbine oil viscosity
  • Dual-barrier seal architecture eliminates any risk of fuel-to-oil cross-contamination
  • Qualified for severe aero-engine vibration spectra and rapid altitude thermal shock
Target Platforms:Aero-Engine & Turbofan Lubrication LoopsAircraft Constant Speed Drive (CSD) / IDG CoolingMain & Accessory Gearbox Thermal Control
Rangsons Aerospace Fuel-Cooled Oil Cooler FCOC (RAPL-HX-FCOC)

Technical Specifications

Up to 15 kW · 600 PSI Fuel Rated
Heat Transfer Rate
Up to 15 kW
Fuel Operating Pressure
Up to 600 PSI
Oil Operating Pressure
Up to 300 PSI
Fluid Mediums
Aviation Turbine Fuel (Jet A-1) / Turbine Oil (MIL-PRF-23699)
Max Operating Temperature
+180°C
Proof Pressure Testing
1.5× maximum operating pressure
Weight
3.2 Kg
Dimensions
32.0 × 14.0 × 14.0 cm
APU & Helicopter Gearbox · 250 PSIModel / Code: RAPL-HX-OC

Oil Cooler Heat Exchanger (Air-Cooled)

Heavy-duty brazed aluminum air-cooled oil cooler optimized for Auxiliary Power Units (APUs), rotary-wing main transmission gearboxes, and airborne hydraulic return circuits.

Key Engineering Features

  • Internal passage turbulators prevent oil channeling under cold-start high-viscosity conditions
  • Thick-walled header and tube construction withstands hydraulic pressure spikes and surges
  • Military airworthiness qualified for high-vibration rotary-wing helicopter transmissions
Target Platforms:Helicopter Main & Tail Rotor GearboxesAirborne Auxiliary Power Units (APU)Military Flight-Control Hydraulic Cooling
Rangsons Aerospace Air-Cooled Oil Cooler Heat Exchanger (RAPL-HX-OC)

Technical Specifications

Up to 10 kW · 250 PSI Operating
Heat Transfer Rate
Up to 10 kW
Operating Pressure
250 PSI
Fluid Medium
Hydraulic Oil (MIL-PRF-5606 / 83282) & Engine Oil
Fin Density
18 FPI (Turbulized / Wavy)
Max Operating Temperature
+150°C
Material
Brazed Aluminum
Weight
2.8 Kg
Dimensions
24.0 × 18.0 × 10.5 cm
Category 03 · Conduction & Micro-Channel Liquid Cold Plates

CEMILAC-Approved Avionics & AESA Radar Liquid Cold Plates

Precision CNC-milled and vacuum-brazed monoblock Aluminum 6061-T6 liquid cold plates achieving thermal resistances down to 0.006 °C/W and surface flatness under 0.02 mm for high-flux GaN Transmit/Receive (T/R) radar arrays and conduction-cooled OpenVPX ATR racks.

0.015 °C/W · UAV & Missile AvionicsModel / Code: RAPL-CP-SS01

Avionics Cold Plate — Single-Sided

Lightweight 0.8 kg monoblock vacuum-brazed Aluminum 6061-T6 single-sided liquid cold plate engineered for localized heat extraction in compact UAV, missile seeker, and flight-control bays.

Key Engineering Features

  • Low-mass 0.8 kg monoblock envelope tailored for SWaP-constrained UAVs and Munitions
  • NADCAP vacuum-brazed joints ensure zero-leak structural integrity under shock loads
  • CFD-balanced internal flow distribution eliminates localized hot spots across PCB footprints
Target Platforms:Tactical UAV Mission ComputersMissile Seeker & Guidance ElectronicsCompact Airborne Power Supplies
Rangsons Aerospace Single-Sided Vacuum-Brazed Avionics Cold Plate (RAPL-CP-SS01)

Technical Specifications

0.015 °C/W Thermal Resistance
Thermal Resistance
0.015 °C/W
Operating Pressure
Up to 120 PSI
Coolant Medium
EGW (Ethylene Glycol Water) / PAO
Helium Leak Rate
< 1 × 10⁻⁶ sccs Helium
Material
Aluminum Alloy 6061-T6 (Vacuum Brazed)
Surface Flatness
< 0.05 mm per 100 mm
Weight
0.8 Kg
Dimensions
18.2 × 15.4 × 1.2 cm
0.011 °C/W · CEMILAC Type-ApprovedModel / Code: RAPL-CP-DS02

Avionics Cold Plate — Double-Sided (CEMILAC Approved)

CEMILAC type-approved double-sided liquid cold plate engineered to cool dual processor boards or high-density RF cards mounted simultaneously on top and bottom precision-milled faces.

Key Engineering Features

  • Double-sided cold mounting planes double electronic packaging density inside LRUs
  • High-density internal offset strip-fin core maximizes convective surface area
  • CEMILAC type-approved for Indian airborne radar signal-processing platforms
Target Platforms:Airborne Radar Signal ProcessorsEW Digital Receiver / Exciter CardsHigh-Density Mission Avionics LRUs
Rangsons Aerospace CEMILAC Approved Double-Sided Avionics Cold Plate (RAPL-CP-DS02)

Technical Specifications

0.011 °C/W · CEMILAC Certified
Thermal Resistance
0.011 °C/W
Operating Pressure
Up to 150 PSI
Coolant Medium
PAO (Polyalphaolefin) / PGW
Helium Leak Rate
< 1 × 10⁻⁷ sccs Helium
Material
Aluminum Alloy 6061-T6 / 3003
Surface Flatness
< 0.03 mm per 100 mm
Certification
CEMILAC Type-Approved
Weight
1.2 Kg
Dimensions
22.5 × 18.0 × 1.4 cm
0.008 °C/W · AESA T/R Module CoolingModel / Code: RAPL-CP-HFR03

Avionics Cold Plate — High-Flux AESA Radar Cooling

Ultra-low-resistance multi-channel liquid cold plate custom-engineered for Active Electronically Scanned Array (AESA) radars and high-power GaN/GaAs Transmit/Receive (T/R) amplifier modules.

Key Engineering Features

  • Purpose-built for GaN/GaAs AESA radar Transmit/Receive (T/R) module array cooling
  • Precision 0.1 mm micro-fin arrays deliver 0.008 °C/W ultra-low thermal impedance
  • Qualified for high-g supersonic fighter aircraft random and sine vibration envelopes
Target Platforms:Fighter Aircraft AESA Fire-Control RadarsHigh-Power Solid-State EW Jammer ArraysAirborne Early Warning (AEW&C) Sensor Arrays
Rangsons Aerospace High-Flux AESA Radar T/R Module Liquid Cold Plate (RAPL-CP-HFR03)

Technical Specifications

0.008 °C/W · 0.1 mm Micro-Fins
Thermal Resistance
0.008 °C/W
Operating Pressure
Up to 180 PSI
Coolant Medium
EGW / PAO / Coolanol
Helium Leak Rate
< 5 × 10⁻⁸ sccs Helium
Material
Aluminum 6061-T6 with AlSiC insertions (optional)
Micro-Fin Geometry
Down to 0.1 mm fin thickness
Surface Flatness
< 0.02 mm over active T/R zones
Weight
2.1 Kg
Dimensions
34.0 × 24.5 × 1.6 cm
0.006 °C/W · 8-Slot Structural Cold WallModel / Code: RAPL-CP-MZ04

Avionics Cold Plate — Integrated Multi-Zone ATR Chassis

Chassis-integrated structural liquid cold plate serving simultaneously as the load-bearing ATR enclosure wall and primary liquid heat sink for up to 8 conduction-cooled VITA/VPX avionics modules.

Key Engineering Features

  • Dual-purpose load-bearing ATR chassis wall and multi-zone liquid heat exchanger
  • Pre-integrated dripless quick-disconnect couplings for rapid flight-line LRU swap
  • MIL-DTL-5541 chromate conversion finish resists naval and coastal salt-fog corrosion
Target Platforms:3U / 6U OpenVPX Conduction-Cooled ATR RacksNaval Combat Management & Sonar CabinetsAirborne Multi-Sensor Fusion Mission Computers
Rangsons Aerospace Integrated Multi-Zone Structural ATR Cold Plate (RAPL-CP-MZ04)

Technical Specifications

0.006 °C/W · 8 VPX/ATR Card Slots
Thermal Resistance
0.006 °C/W
Operating Pressure
Up to 200 PSI
Coolant Medium
PAO / EGW / Deionized Water
Helium Leak Rate
< 1 × 10⁻⁷ sccs Helium
Material
Vacuum-Brazed Monoblock Aluminum
Surface Protection
Chromate Conversion Coating (MIL-DTL-5541)
Module Capacity
Supports up to 8 conduction-cooled cards
Weight
3.5 Kg
Dimensions
42.0 × 30.5 × 2.2 cm
Category 04 · Self-Contained Tactical Store Thermal Control

Airborne EW Pod Cooling System (MIL-STD-810 Qualified) & Sub-Assemblies

Complete active PAO aerospace cooling system engineered for full EW pod cooling MIL-STD-810G/H compliance across external 10-inch and 14-inch military Electronic Warfare (EW) self-protection jammer pods, radar pods, -40°C to +55°C ambient extremes, 25g shock, 7.7g RMS vibration, and 45,000 ft altitude.

3.5 kW Capacity · Mach 0.95 · 45,000 ftModel / Code: RAPL-POD-EW01

EW Pod Cooling System (Self-Contained Active Liquid Loop)

Flight-qualified, self-contained active liquid and vapor-cycle thermal management system engineered for external 10-inch and 14-inch tactical Electronic Warfare (EW) self-protection jammer pods and airborne sensor pods.

Key Engineering Features

  • Complete drop-in active cooling unit integrating compressor/monoblock, pump, accumulator, LCM, and digital controller
  • Engineered for standard 10-inch and 14-inch external fighter EW jammer and reconnaissance pod cross-sections
  • Automatic thermal bypass valve prevents PAO over-cooling and viscosity lock during high-altitude cold soak
Target Platforms:Tactical Fighter Electronic Warfare (EW) Jammer PodsDcPP Airborne Self-Protection Suites (ECM / ESM / RWR)Podded EO/IR Targeting & Reconnaissance Systems
Rangsons Aerospace 3.5 kW EW Pod Cooling System Assembly (RAPL-POD-EW01)

Technical Specifications

Up to 3.5 kW · Mach 0.95 / 45,000 ft
Cooling Capacity
Up to 3.5 kW continuous
Ambient Operating Temperature
-40°C to +55°C
Flight Envelope
Up to Mach 0.95 · Altitude up to 45,000 ft
Coolant Medium
Polyalphaolefin (PAO)
Electrical Power Input
115V AC, 3-Phase, 400Hz
Control Architecture
Microprocessor-based automatic temperature & thermal bypass control
Pod Compatibility
Standard 10-inch and 14-inch military EW / sensor pod structures
Integrated Sub-Assemblies
Monoblock, Liquid Cooling Module (LCM), Coolant Pump, Accumulator
Weight
18.5 Kg
Dimensions
58 × 32 × 28 cm
LRU Breakdown · Inside RAPL-POD-EW01

Flight-Qualified Pod Cooling Sub-Assemblies

Available as complete pod system or custom-packaged LRUs
EW Pod Cooling Monoblock Vacuum-Brazed Heat Exchanger Core
RAPL-POD-MB

Monoblock Heat Exchanger Core

Compact vacuum-brazed monolithic heat-rejection core integrating ram-air fin passages with internal PAO manifolds for zero-weld-seam structural endurance under external store flight loads.

EW Pod Liquid Cooling Module (LCM) Conditioning Assembly
RAPL-POD-LCM

Liquid Cooling Module (LCM)

Integrated fluid-conditioning manifold housing precision temperature/pressure telemetry sensors, filtration, thermal bypass valving, and dripless interface ports for jammer cold plates.

Aerospace 400Hz PAO Coolant Circulation Pump for EW Pod Cooling
RAPL-POD-PMP

Aerospace Coolant Pump

High-reliability 400Hz brushless aerospace circulation pump engineered to maintain constant PAO mass flow across high-delta-P micro-fin jammer cold plates during high-g combat maneuvers.

Pressurized Thermal Expansion Accumulator for Airborne Pod Cooling
RAPL-POD-ACC

Pressurized Accumulator

Hermetically sealed bellows/piston thermal expansion accumulator compensating for PAO fluid volume change from -40°C cold soak at 45,000 ft to +55°C desert tarmac standby while preventing pump cavitation.

Proven on Landmark Indian & Global Aerospace Programs

Orbital Spaceflight, Deep-Sea & NADCAP Digital-Twin Manufacturing

Every heat exchanger, cold plate, and pod cooling loop is backed by Rangsons Aerospace's 100,000+ sq.ft. Mysuru NADCAP special-process complex and Bengaluru thermal engineering center.

ISRO Gaganyaan & NIOT Samudrayaan

Human-Rated Space & 6,000m Deep-Sea Conditioning

Rangsons engineers integrated crew-module thermal and humidity control validation systems for ISRO's Gaganyaan human spaceflight mission (400 km LEO) and supports system integration and acceptance testing on NIOT's Matsya 6000 manned submersible.

Explore Gaganyaan & Samudrayaan Programs
ThermoTwin Digital Twin

AI-Driven Vacuum Brazing Cycle Optimization

Our NADCAP aluminum vacuum-brazing furnaces leverage ThermoTwin—Rangsons' proprietary 3D IGES and FEM/FDM heat-transfer Digital Twin software—to simulate core thermal gradients and eliminate brazing distortion before first-article manufacture.

Inspect ThermoTwin Software Architecture
Full Qualification Pedigree

AS9100D, NADCAP, CEMILAC & TVAC Validated

Complete in-house and accredited verification including Thermal Vacuum Chamber (TVAC) cycling, Helium mass-spectrometry leak testing (< 5×10⁻⁸ sccs), hydrostatic proof/burst testing, pressure impulse, and 3-axis MIL-STD-810H / DO-160G vibration qualification.

View Bengaluru & Mysuru Facilities
Procurement & Thermal Systems Engineering Q&A

Frequently Asked Questions — Aerospace Thermal Management

Technical answers for OEM thermal architects, DRDO/ISRO program offices, and aerospace procurement teams evaluating custom Build-to-Spec or Build-to-Print heat transfer hardware.

What custom thermal management products, heat exchangers, and aerospace cooling systems does Rangsons Aerospace manufacture?

Rangsons Aerospace designs and manufactures custom thermal management products and aerospace cooling systems in Mysore (Mysuru) and Bangalore (Bengaluru), Karnataka using NADCAP-accredited vacuum brazing. Our aircraft cooling solutions cover Air-to-Air Heat Exchangers (up to 5 kW, -55°C to +250°C), Air-to-Liquid Radiators (up to 8 kW, 450 PSI burst), Liquid-to-Liquid Heat Exchangers (up to 12 kW, >85% effectiveness, <1×10⁻⁶ sccs He), Three-Core Heat Exchangers (up to 25 kW across 3 circuits), Fuel-Cooled Oil Coolers (FCOC, up to 15 kW), and Air-Cooled Oil Coolers (up to 10 kW).

What thermal resistance and Helium leak-rate performance do Rangsons Avionics Cold Plates achieve for AESA radars?

Our vacuum-brazed monoblock Aluminum 6061-T6 liquid cold plates span four standard classes plus custom Build-to-Spec geometries: Single-Sided Cold Plates (0.015 °C/W, 0.8 kg), CEMILAC type-approved Double-Sided Cold Plates (0.011 °C/W, <1×10⁻⁷ sccs He), High-Flux AESA Radar T/R Cooling Cold Plates (0.008 °C/W using 0.1 mm micro-fins, <0.02 mm flatness, optional AlSiC inserts, and <5×10⁻⁸ sccs Helium leak integrity up to 180 PSI), and Integrated Multi-Zone ATR Structural Cold Plates (0.006 °C/W supporting up to 8 conduction-cooled cards at 200 PSI).

How does the Rangsons 3.5 kW EW Pod Cooling System meet MIL-STD-810 compliance and extreme flight envelopes?

The Rangsons EW Pod Cooling System (RAPL-POD-EW01, 18.5 kg, 58 × 32 × 28 cm) is an active aircraft cooling system delivering up to 3.5 kW continuous Polyalphaolefin (PAO) cooling engineered for full MIL-STD-810G/H compliance across -40°C to +55°C ambient temperatures, up to Mach 0.95 and 45,000 ft altitude, 25g shock, 7.7g RMS vibration, and condensing humidity. Running on 115V AC 3-Phase 400Hz power, it integrates four flight-qualified sub-assemblies—the vacuum-brazed Monoblock core, Liquid Cooling Module (LCM), brushless Coolant Pump, and pressurized Accumulator—with an automatic thermal bypass valve for 10-inch and 14-inch military pods.

How does Rangsons Aerospace support ISRO's Gaganyaan human spaceflight thermal management?

For ISRO's Gaganyaan crewed orbital spaceflight programme (400 km Low Earth Orbit), Rangsons Aerospace contributes integrated crew-module thermal and humidity control engineering, thermal performance validation, Thermal Vacuum Chamber (TVAC) testing, and system-level human-rating qualification support.

Which coolants, aviation oils, and airworthiness standards are supported across your aerospace cooling solutions?

Our aerospace cooling systems support Polyalphaolefin (PAO), Ethylene Glycol Water (EGW), Propylene Glycol Water (PGW), Coolanol, deionized water, Jet A-1 aviation turbine fuel, and military lubricants (MIL-PRF-23699, MIL-PRF-5606, MIL-PRF-83282). Manufacturing in Mysuru, Karnataka runs under AS9100D, ISO 9001:2015, and NADCAP Vacuum Brazing accreditation, with flight qualification to CEMILAC, DGAQA, MIL-STD-810G/H, and DO-160G.

How does ThermoTwin improve NADCAP aluminum vacuum brazing reliability?

Rangsons pairs its Mysuru vacuum-brazing furnaces with ThermoTwin—our proprietary AI-driven 3D Digital Twin platform that ingests IGES CAD assemblies and alloy properties to run coupled FEM/FDM thermal simulations, optimizing soak temperatures and preventing core distortion prior to physical brazing.

Build-to-Spec & Build-to-Print Thermal Engineering

Consult With Our Aerospace Thermal & CFD Design Team Under NDA

Share your heat load, pressure-drop budget, coolant specification, and envelope constraints. First-article flight-qualified prototypes typically ship in 8 to 14 weeks from our Mysuru and Bengaluru complexes.

Request for Enquiry